This is perfect for achieving a reduced data centre PUE. With continuous monitoring the UPS switches to the inverter within 2ms should the control system experience any anomalies. The parallel control system tightly manages both active and reactive type loads, allowing for intelligent load/current sharing between each individual module. It features smart online (SOL) mode, which significantly reduces energy consumption as the load is fed primarily through the bypass line. The B9000 UPS can be configured to operate in parallel, offering an N+1 configuration or alternatively as a power expansion option. Borri UPS: List of Devices Model Type of Document 1: Borri ASD91: Borri UPS ASD91 Operating manual (226 pages) 2: Borri ASD92: Borri UPS ASD92 Operating manual (226 pages) 3: Borri ASD93. The parallel control system tightly manages both active and reactive type loads, allowing for intelligent load/current sharing between each individual module. Why a UPS The B9000 is designed to protect against electrical threats that frequently affect a computerised infrastructure. 18 Borri UPS Manuals and User Guides (73 Models) were found in All-Guides Database. ABM (Accurate Battery Management) funkcija za lako upravljanje baterijama. Pametan ureaj sa funkcijama FleXible i Smart, niskim ulaznim THD i faktorom snage 0,99 za poboljavanje kompatibilnosti sa mrenim napajanjem i generatorom. Fully compliance with all international product standards for maximum quality guarantee.The B9000 UPS can be configured to operate in parallel, offering an N+1 configuration or alternatively as a power expansion option. Borri B9000FXS UPS sa dvostrukom konverzijom prua zatitu za svaki ureaj.Comprehensive set of communication options for total remote monitoring of equipment operation.CAN-bus based distributed parallel control ensuring high load sharing accuracy and no single point of failure in parallel systems.Dual DSP plus microcontroller logics for top performance and reliability.Power and redundant parallel configurations with distributed or centralized static bypass for high fault current management.Smart parallel management in load sharing or load synchronization of two UPS and load synchronization of two paralleled systems for optimum protection.Dynamic Charging Mode (DCM) for maximum versatility in long autonomy and low charging time applications.Accurate battery management providing ripple current minimization charge current/voltage control as per batteries manufacturers’ specifications and automatic/manual battery test for maximum battery expected life preservation.Hot connection/disconnection of paralleled units for easy system resizing.Front access to all critical components for easy maintenance.Full IGBT technology and electronic PFC, ensuring 0.99 input PF and THDi.Built-in inverter transformer for DC-AC galvanic protection of industrial type loads.Planning, installation, commissioning.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
March 2023
Categories |